4
replies
MKVI - Synch. Permissive Trouble (K25P - TTUR)
Posted by vince64 on 17 November, 2015 - 5:18 pm
Synchronization not working: permissives ok but K25P not activated; auto synch ok, K25 is activated at each synch turn; no closing command for the 52G breaker
4
replies
Chromalox Temperature Controller Alarm Output
Posted by TheSource on 17 November, 2015 - 11:26 am
Looking for some input or guidance on getting 120V output for an audible alarm on a chromalox temperature controller.
3
replies
Mapping Registers to Data Reference
Posted by Juergen on 17 November, 2015 - 7:47 am
I do not know how I have to map our generator paramters to the MODBUS TCP Addresses.
9
replies
Fire Mode
Posted by Maythem on 17 November, 2015 - 6:13 am
What is the main uses of fire mode?
1
reply
PLC and Gear Motor help
Posted by AlfredoAMD on 17 November, 2015 - 12:51 am
Trying to find a proper combination of a PLC and Gear Motor for a simple chain conveyor system I'm developing.
2
replies
Questions About Combustion Nozzle Design
Posted by jameelrahman on 16 November, 2015 - 1:04 pm
Trainee engineer in gas power plant has questions about combustion nozzle design.
2
replies
M-bus to USB/RS-232 adapter to Convert M-bus to MODBUS
Posted by brandons on 16 November, 2015 - 3:50 am
Looking for a recommendation on an m-bus to usb/RS-232 converter to convert from m-bus to MODBUS
4
replies
Fire and Gas System / Safety Instrumented System
Posted by allenbradley on 15 November, 2015 - 1:44 pm
Is FGS linked with SIS?
Citect Modbus with FloBoss600
Posted by hany5757 on 15 November, 2015 - 11:47 am
Have the CPU of floboss 600 flow computer with its front panel and no screen. How to access the data that sent from it to Citect HMI through MODBUS?
2
replies
Is an Automation engineer in India a Diploma Level or technician Level Job?
Posted by Rushi Shroff on 15 November, 2015 - 8:03 am
Is job of an Automation engineer in India merely 'Diploma level' or technician level?
Microsoft Message Analyzer
Posted by EuroEager on 15 November, 2015 - 4:46 am
Microsoft Message Analyzer capabilities for Modbus
Problem Saving Data on Delta PLC
Posted by mahshid on 15 November, 2015 - 3:34 am
Delta PLC overwriting data at shutdown
1
reply
Modicon Quantum Failure
Posted by maticman38 on 14 November, 2015 - 8:40 pm
Hi, I'm new to this forum. Modicon Quantum PLC fault.
3
replies
How Many PLCs Are Required
Posted by manmod on 14 November, 2015 - 1:30 am
How many PLCs are you using in an oil/gas measuring station?
4
replies
MODBUS with Different Power Supplies
Posted by Azayel on 13 November, 2015 - 9:41 pm
MODBUS, two different power supplies 12V and 24V.
7
replies
Control Valve Sizing
Posted by anaalmansuri on 13 November, 2015 - 5:33 pm
Control Valve Cavitation Problem
Bently Nevada Vibration Monitor
Posted by allenbradley on 13 November, 2015 - 3:35 pm
Connecting/using Bently Nevada vibration monitors
1
reply
MODBUS Device Interface Segregation
Posted by Matthew Raterman on 13 November, 2015 - 2:10 pm
Best practices for separating various devices communicating to a MODBUS master to minimize communication failures.
1
reply
Fire and Gas Control Panel Configuration
Posted by fatimafert1 on 13 November, 2015 - 11:43 am
Promel FGP 04 communication problem on GE gas Tubine
2
replies
What Will Happen if Delta Connected Motor in STAR
Posted by Gmahesh on 13 November, 2015 - 2:04 am
Motor winding heated due to wrong connection?
Voltage Control Generator
Posted by Taha Omar on 12 November, 2015 - 3:30 pm
how can a voltage control generator supply real and reactive power?
4
replies
MODBUS TCP over IPSec VPN
Posted by Eradz on 11 November, 2015 - 6:45 pm
Trying to get MODBUS TCP over IPsec VPN
4
replies
3051 Capsule Transmitter Out of Range
Posted by junah on 11 November, 2015 - 2:06 am
3051 capillary transmitter out of range problem
3
replies
1771-IL Manual
Posted by Bruce427 on 10 November, 2015 - 8:34 pm
Need manual for an old 1771-IL isolated input module. SERIES A - Rev B
5
replies
Experion PKS Display Blackout/Inverted Video
Posted by mcwv on 10 November, 2015 - 7:08 pm
After DCS conversion from Foxboro I/A to Honeywell Experion PKS R430, analog values will flash black for one refresh rate periodically.
7
replies
Emergency Lube Oil Pump for ALSTOM 13E2
Posted by sudamadhav on 10 November, 2015 - 6:41 pm
Emergency lube oil pump for 13E2 is designed on what basis? For 13E2 its a twin speed; why twin speed?
Time Synchronisation in GE 369 and 469
Posted by Noor on 10 November, 2015 - 1:54 pm
I want to time synchronize GE 369 and 469 relays
1
reply
QA Testing... Beyond Point 2 Point
Posted by Gage_Stryker on 9 November, 2015 - 5:43 pm
When point to point fails to pick up wiring issues...
1
reply
Internal Failure Message in Atlas Copco Air Regulator
Posted by govoni2015 on 9 November, 2015 - 3:27 pm
Atlas Copco Air Regulator Electronikon shutdown and is flashing error
Sewer Backup Problem
Posted by Bernie V on 9 November, 2015 - 2:51 pm
Looking for equipment to monitor building sewer line flow so we can be alerted to an imminent backup.
2
replies
MODBUS on Siemens S71200 PLC
Posted by urimadar on 8 November, 2015 - 10:30 am
Writing to Siemens S71200 PLC using TCP/IP MODBUS
3
replies
Air Coming from AA Booster Compressor Body Vents
Posted by barindra75 on 8 November, 2015 - 6:40 am
Mild hot air is coming out from AA booster compressor body vent holes when booster compressor is not in operation.
Steam Turbine Load Reduction
Posted by Sandeep on 8 November, 2015 - 5:07 am
Steam turbine load reduction
1
reply
Mark VIe - Live and Initial Value
Posted by Sardar99 on 8 November, 2015 - 3:08 am
Can somebody explain me what are the live value and Initial value?
SIMOCODE with TIA Portal
Posted by Jamal Hamdan on 7 November, 2015 - 5:43 pm
SIMOCODE with TIA Portal
18
replies
MW Hunting in GT
Posted by vinayak_paranjape on 7 November, 2015 - 1:31 pm
MW hunting in Gas Turbine
SAPCV That Will Reduce and Control from 8 bar to 0.1 bar
Posted by VJ on 7 November, 2015 - 7:52 am
Looking for a self-regulating valve that can reduce and control from 8 bar to 0.1 bar output
1
reply
Excitation Control of Hydrogenerator
Posted by manojbaral on 7 November, 2015 - 4:01 am
Field voltage of brushless excitation system for a hydro-generator of 22 MVA capacity
13
replies
Slow Level PID Loop
Posted by Ormo on 6 November, 2015 - 7:50 pm
Slow level PID loop with telemetry delay
2
replies
Safety Barriers and Isolators
Posted by AllenBradley on 6 November, 2015 - 10:46 am
How does process transmitters function when it is connected to a barrier or isolator?
1
reply
AB OB16E Electronic Fuse Tripping
Posted by mjtracy on 6 November, 2015 - 10:43 am
I am getting a Fuse LED lit up on my 1756-OB16E output module when energizing multiple output channels.
Isentropic Efficiency Calculations
Posted by AdamIR on 6 November, 2015 - 3:55 am
Calculating isentropic efficiency for compressors, not sure about absolute pressure
4
replies
Inter Domain Communication Issue in Yokogawa DCS after Upgrade
Posted by Kaleemullah Memon on 5 November, 2015 - 10:41 pm
Inter Domain Communication Issue in Yokogawa DCS after Upgrade from CS3000 to VP R5.04
2
replies
Safety PLCs
Posted by BillyMac on 5 November, 2015 - 9:09 pm
Learning about safety PLCs
6
replies
Migration from SLC500 to 5000
Posted by BillyMac on 5 November, 2015 - 9:02 pm
Time to migrate to 5000 platform
3
replies
Yokogawa Centum VP 4.03 in Windows 7 environment
Posted by Bolek on 5 November, 2015 - 3:14 pm
I need to install Centum VP 4.03 on HIS in Windows 7 environment.
5
replies
Recommended Low-Cost Modbus RTU Mixed-Signal Remote I/O Module
Posted by beck92 on 5 November, 2015 - 12:35 pm
Seeking recommendations for a simple, low-cost Modbus remote I/O module w/ analog I/O, digital I/O, 2A+ relays
2
replies
Provox Algorithm
Posted by betress on 5 November, 2015 - 12:00 pm
Has anyone converted Series PID Algorithms to Velocity PID Algorithms?
1
reply
Can No Longer Verify MODBUS String from Slave Device
Posted by SMF on 5 November, 2015 - 8:27 am
Modscan software quit working suddenly, and I cannot reestablish communication with slaves.
Communication between SI580E and PLC Modicon 340
Posted by hassansaper on 5 November, 2015 - 5:58 am
How to read data via RS 485 from Load Cell indicator SI 580E in Unity Pro
SIL Calculation for HIPPS Loop
Posted by SpecialProjects on 4 November, 2015 - 11:13 pm
When to use Risk Reduction Factor (RRF) in SIL calculations
23
replies
GCV Fluctuations
Posted by bkarim55 on 4 November, 2015 - 2:20 pm
Could the GCV Instability to be the reason that the GT goes to Exhaust temperature Control?
2
replies
Interfacing Printer with a Light Signaling Incoming FAX
Posted by Lance on 4 November, 2015 - 1:13 pm
Can a printer/fax machine act as an input for a lamp to signify incoming faxes?
Small Address Model MODBUS
Posted by Marcelo Mancilla on 4 November, 2015 - 10:40 am
How to read MODBUS registers with small address mode and convert to MODBUS register to large mode (1-49999)?
1
reply
E stops
Posted by engineer1000 on 4 November, 2015 - 4:54 am
Type of 2 core wire to use to wire e stops together
1
reply
Robot E-stop over Ethernet - Guardlogix
Posted by RoboKD on 3 November, 2015 - 1:15 pm
Guardlogix Ethernet module to robot safety
MODBUS Link with VFD
Posted by REJIN GEORGE on 3 November, 2015 - 6:04 am
Encountering a VFD-PLC communication problem while communicating with HMI
Getting Error Code 0x01 While Doing Transmission
Posted by BPatel on 3 November, 2015 - 5:44 am
Modbus TCP Frame giving 0x01 error message.
Difference Between an AC-DC-AC Inverter and AC Inverter
Posted by Gama81 on 2 November, 2015 - 10:52 pm
What are the differences between an AC-DC-AC inverter and an AC inverter, even the DC inverter?
1
reply
Alternator Stator Windings Insulation
Posted by champion_ip4p on 2 November, 2015 - 5:50 pm
How far does VPI are water resistant?
5
replies
Air Extraction from Compressor Discharge
Posted by Obiloko4 on 2 November, 2015 - 11:06 am
Cooling of extracted air from compressor discharge.
4
replies
Piggyback 4-20 ma Signal from DP Transmitter?
Posted by acmercg on 2 November, 2015 - 9:23 am
Need to mate a new system with old one. Can I piggyback 4-20ma signal from DP transmitter?
1
reply
S5 1430 TCP connection
Posted by bobmarcel on 2 November, 2015 - 12:46 am
How to establish communication between S5 115U via CP1430 TCP and S7 using a TCP connection with out ISO on TCP connection?
1
reply
Auto Transformer Issues
Posted by azizam on 1 November, 2015 - 10:45 pm
Auto transformer with automatic on load tap changer
1
reply
Interested in Learning Allen-Badley PLCs?
Posted by sdgates on 1 November, 2015 - 10:26 pm
Looking for feedback from potential/future Allen-Bradley users.
5
replies
Gas Turbine GE PG9171E Flow Parameters
Posted by AAK on 1 November, 2015 - 11:56 am
Gas turbine PG 9171E design flow parameters are required. Gt inlet air flow, Gt exhaust air flow and air flow from 5 stage (cooling and sealing air).
CT Polarity and Reverse Power
Posted by habdellatif on 1 November, 2015 - 4:09 am
Generator CT polarity and effect on the reverse power relay and other functions.
2
replies
HMI 4.01 Troublshooting
Posted by elinordo on 1 November, 2015 - 4:04 am
HMI 4.01 troublshooting for MARK5 under Windows 95NT
2
replies
Communication between PLC and Digital relays in Switchgear
Posted by charzree on 1 November, 2015 - 2:58 am
Communication between PLC and Digital relays in switchgear
4
replies
MARKV: R core A8 status and Bad EEPROM Checksum Error
Posted by Esoteric_Stone on 31 October, 2015 - 4:50 pm
After exhaust thermocouples were showing bad readings on the HMI, R core found in A8 status
5
replies
Pressure Sensor that Inverts a 4-20ma Signal
Posted by mike mckenna on 31 October, 2015 - 2:19 pm
Reverse signal sensor or a signal reverser.
2
replies
What does the alarm "diagnostic alarm TCQA servo current #2 disagrees W/Ref" mean?
Posted by bil07 on 30 October, 2015 - 1:57 pm
Can anyone explain what the following alarm means "diagnostic alarm TCQA servo current #2 disagrees W/Ref"?
2
replies
Jacking Oil Pump for Steam Turbine/Generator
Posted by premkumar on 30 October, 2015 - 5:01 am
What is the basis for deciding to provide Jacking Oil for Stem Turbine or for Generator or Both.
2
replies
GE Mark VI Tci Log
Posted by Esganfia on 29 October, 2015 - 8:51 pm
Tcilog/gsm.log interpretation (alarm flood issues)
2
replies
Absolute Encoder Position Data Evaluation
Posted by cjswish on 29 October, 2015 - 5:20 pm
Need help with decoding industrial protocol sensor data
2
replies
Is 450 Feet to Far for Accurate Pressure Sensor Readings?
Posted by ampman on 29 October, 2015 - 4:34 pm
I have a micro 1100. Need to run both pressure sensors 450 ft.
3
replies
Separation of MODBUS Devices
Posted by Matthew Raterman on 29 October, 2015 - 11:36 am
Rule or best practices for separation of multiple devices communicating to a DCS via MODBUS TCP/IP - how to choose what devices go to what cards and are paired together.
4
replies
Stopping Main and Standby Lube Oil Pumps on Discrepancy
Posted by premkumar on 29 October, 2015 - 7:47 am
Do we have to Stop the Main and Stand By Lube Oil Pumps upon Discrepancy?
9
replies
Multi Baud Rate on the Same RS485 MODBUS RTU Bus
Posted by Denaize on 29 October, 2015 - 7:04 am
is it possible to have different baud rate for each slave on RS485 MODBUS RTU bus?
3
replies
Kepware ClientAce examples
Posted by wwlederer on 29 October, 2015 - 4:33 am
Where are descriptions for the Kepware examples embedded in ClientAce? Where are projects related to the existing descriptions?
Radar Gauge - Wrong level Indication
Posted by J C Das on 29 October, 2015 - 1:27 am
Variation in reading of Radar Level Gauge
GE PLENETG04 Integration
Posted by mtbuntrock on 28 October, 2015 - 11:45 pm
Looking for someone that has integrated to a GE PLENETG04.
1
reply
Connecting Generator Rated 18KV to GSU Rated 17 kv
Posted by krishnakka on 28 October, 2015 - 2:36 pm
Connecting 18KV rated generator to 17KV rated transformer.
8
replies
AVR Drop
Posted by Saied on 28 October, 2015 - 11:50 am
Synch Gen can produce positive Mvar or use negative Mvar. What's AVR rule in this process?
4
replies
MODBUS RTU Hardware Connection
Posted by rfan on 28 October, 2015 - 8:04 am
Using a ST485EC transceiver for MODBUS RTU communication. Do A and B match and MODBUS A and B directly?
3
replies
Gas Turbine Starting System (Diesel Engine) Reliability Check
Posted by khlatif on 28 October, 2015 - 6:48 am
Can the diesel engine of gas turbine be tested by starting it while the gas turbine is in normal operation?
5
replies
CPD Pressure
Posted by dontknowman on 28 October, 2015 - 6:21 am
How CPD pressure change from 5 to 10 bar when generator breaker closes?
2
replies
Difference Between Profibus DP and Profibus PA
Posted by Kingrosekhan123 on 27 October, 2015 - 11:26 pm
what are the differences between Profibus DP and Profibus PA?
Modbus TCP communication between PLC and RFID
Posted by mlirici on 27 October, 2015 - 1:00 pm
Has anyone done a communication between a Modbus TCP PLC and an RFID with ISO14443
Foxboro 144LD Level Transmitter Has Interfacing Issues with Emerson Delta V DCS
Posted by manojc_24 on 27 October, 2015 - 5:32 am
Does a Foxboro 144LD level transmitter have interfacing issues with Emerson Delta V DCS? Foxboro 144 LD makes the faceplate controller randomly go into manual. The only solution to get it back to auto is to restart the LT.
Configuring Siemens VFDs
Posted by youngcontroleng on 26 October, 2015 - 6:14 pm
Looking for help with configuring Siemens VFDs, using the BOP-2 Operational pad to enter drive parameters and allocate terminals.
9
replies
Counter Negative
Posted by grajesh on 26 October, 2015 - 7:13 am
GE-9E unit gas flow totalized counter started reading negative while unit is running
2
replies
Mandatory Control Valve Feedback
Posted by azylan on 26 October, 2015 - 4:51 am
Is it mandatory to provide Control Valve's feedback?
Available Processor List Udate with Unity pro XL 8.1
Posted by Reivax76 on 25 October, 2015 - 11:49 am
How to update the available processor list in Unity pro XL V8.1?
5
replies
MKV HMI Upgrade From Window XP to WorkStationST
Posted by barswann on 25 October, 2015 - 11:17 am
HMI Not Receiving Signal From the MK V After Upgrade From Windows XP to Windows 7 With WorkstionST
No Communication between LM 90 and Fanuc CPU 311
Posted by asif shah on 25 October, 2015 - 3:43 am
After installing LM 90 and GE Fanuc CPU 311 received warning message saying PLC is offline and monitor key switch not present.
Critique of College Project - Control of Servo Motor
Posted by ControlPhreak on 24 October, 2015 - 10:04 am
Need help in an academic work regarding position control.
1
reply
Modbus TCP Reading Error with 32 Bit Floating Point HR
Posted by Luis Aiassa on 23 October, 2015 - 2:36 pm
Error while reading a 32 bit holding register in a Honeywell masterlogic 50 PLC, using MODBUS TCP protocol to poll the PLC with inductive automation SCADA software.
1
reply
DC Lube Oil Problem
Posted by abdullahalyaqoubi on 23 October, 2015 - 12:57 pm
DC lube oil is start with out any problems with pressure and setting pressure switch
1
reply
Frame 9E Low CPD
Posted by Obedia_pass on 23 October, 2015 - 9:46 am
low CPD of Frame 9E after major inspection and compressor change