Member Information and Posts by David_2
Topic: Communications systems and equipment.
from the Modbus, Wireless Networking department...
Problems reading Modbus input registers
Originally posted by Barry.C. on 18 June, 2013 - 6:58 am
Trying to read modbus input registers from a WirelessHART gateway. getting fixed values at all input register addresses when they are mapped to varying sensors.
New Replies:
The first thing that comes to mind when you write, "When I try to poll input registers"...
Topic: Engineering and workplace issues.
from the Forum department...
HP MEG filtration DP Tx Selection
Originally posted by anthony brown on 1 May, 2013 - 4:13 pm
DP transmitter selection for HP MEG filtration
New Replies:
1) A datum is missing - what is the expected DP range? It's a filter application, but is the...
Topic: Communications systems and equipment.
from the Forum department...
DPU2000R MODBUS Communication
Originally posted by hatemhabib on 8 May, 2013 - 5:01 am
DPU2000R Modbus communication with SCADA using RS-485 but no response although RS-232 is working properly
New Replies:
Some comments on RS-485 or converters 1) I never use a port powered converter on a laptop...
Originally posted by Tommy on 8 May, 2013 - 6:04 pm
Anyone know manufacturers that make similar valves out there? As trying to avoid piping modification.
New Replies:
Maybe you'd want to take some measurements, make a drawing and post it on site where it could be...
Topic: PLCs and related questions.
from the Engineering department...
Modbus remote I/O for Cl. 1 Div 1?
Originally posted by Frank Seipel on 12 May, 2013 - 7:45 pm
Modbus I/O for hazardous locations
New Replies:
I waited 2 weeks to see if anyone would answer because I don't know of a Cl 1, Div 1 remote I/O box...
Topic: Communications systems and equipment.
from the Maint/Ops department...
Modbus Comms between 2 devices
Originally posted by Fox on 16 May, 2013 - 9:25 pm
New to Modbus, trying setup communication between two devices.
New Replies:
Q1. How do I know who is the master and which is the slave? Do I decide? Would DCS be the master or...
Originally posted by The miracle worker on 10 February, 2013 - 12:08 pm
Possible issue with WX compensation cable to DCS reading of Thermocouple temperature?
New Replies:
> Can i know, what will be the temperature reading in the DCS when Thermocouple burnout occurs? ...
A 5°C error (maybe greater) is possible with some handheld digital thermocouple thermometers...
Topic: Communications systems and equipment.
from the Forum department...
Mobus slave Address
Originally posted by UY on 21 May, 2013 - 9:42 pm
About modbus protocol
New Replies:
I don't know what 248 to 255 are used for. They're not used because that's what the Modbus spec...
Topic: Continuous process industries, DCS questions.
from the Design department...
RS232C to MODBUS Interface
Originally posted by Anand on 18 May, 2013 - 3:44 pm
Request for help related to appropriate hardware-software interface
New Replies:
It isn't a Modbus master you're looking for, it's some other set of functions relating to what...
Topic: PLCs and related questions.
from the Forum department...
Why 250mA fuse for 4-20mA analog input?
Originally posted by Mohamad Ashour on 9 May, 2013 - 5:31 pm
Why 250mA fuse for 4-20mA analog input?
New Replies:
I suspect that a fuse installed in a 4-20mA loop is an attempt to protect an analog input on a 2...
Topic: PLCs and related questions.
from the Forum department...
Modbus Register read
Originally posted by Erik on 6 May, 2013 - 4:55 pm
Howto read Modbus registers to a HMI
New Replies:
My recommendation is to use a generic Modbus master, like Win-Tech's Modscan32 in order to be able...
Topic: Local and wide area networking in factory automation.
from the Forum department...
Network control of 4-20ma output
Originally posted by Rob on 4 May, 2013 - 11:31 am
Network control of 4-20ma output
New Replies:
I've used the WebRelay, and the people who make it have a catalog of control-via-web stuff. But...
A colleague used a Red Lion Data Station Plus (DIN rail mount control module with serial and...
Topic: Communications systems and equipment.
from the Dept of Bento Boxing department...
ModBus Plus
Originally posted by Joe on 1 May, 2013 - 9:14 am
ModBus Plus
New Replies:
4-5 years ago I stopped by the Modbus booth at the national ISA show. I told the booth guy that...
Topic: Communications systems and equipment.
from the Forum department...
terminating resistor
Originally posted by engineer on 2 May, 2013 - 11:48 am
terminating resistor
New Replies:
This 7 minute video on youtube, Reflected waves on a cable, shows the distorted waveform on an...
Topic: PLCs and related questions.
from the Spare materials needed department...
Looking for source of manual control units
Originally posted by Curtis Brown on 25 April, 2013 - 12:20 pm
Our process control systems are run by PLCs and have manual backup panel mounted in the control room. The OEM has gone to a semi- computerized MBU.
New Replies:
I've heard that the US nuclear power industry is served by some companies that reverse engineer and...
Topic: Sensor technologies.
from the Forum department...
Turbine flowmeter error
Originally posted by Petre Popescu on 22 April, 2013 - 2:42 am
Turbine flowmeter reading much more than should be
New Replies:
> maybe there was something wrong with the mechanical transmission between the turbine and the...
Topic: Application Questions and Problems
from the Automation List department...
MicroLogix RTD cards
Originally posted by Mark Riche on 25 April, 2013 - 12:41 pm
Measurement errors in Allen Bradley MicroLogix RTD cards
New Replies:
I've had to 'calibrate' one PAC controller (not an AB uLgx) at its working temperature in its very...
Topic: Continuous process industries, DCS questions.
from the Forum department...
RTD
Originally posted by Sakram on 13 April, 2013 - 12:09 pm
RTD PT110 and PT10 connection to DCS RTD Module in Yokogawa Centum VP.
New Replies:
If your existing analog input module does not support either - your types of RTDs, or - generic...
Originally posted by praveen on 7 April, 2013 - 3:35 pm
Temperature compensation for density variation of air in hydrostatic measurement
New Replies:
FYI, a year ago, maybe two years ago, a forum topic involved diminishing air pressure in a closed...
Topic: Information resources, documentation.
from the KID department...
MODBUS Address
Originally posted by RAMA on 30 March, 2013 - 2:42 am
MODBUS Address - how to identify?
New Replies:
The Modbus Standard Modbus over Serial Line V1.02 (downloadable for free at Modbus.org) says: ...
Topic: Communications systems and equipment.
from the Student KaHo Sint-Lieven Gent, Belgium department...
Modbus RTU NO_RESPONSE
Originally posted by Dries Van den Broeke on 29 March, 2013 - 9:37 am
Slave Device does not respond to the master.
New Replies:
2 wire RS-485 is implemented differently from manufacturer to manufacturer. Although you might...
Topic: Communications systems and equipment.
from the Forum department...
Problem with energy meter using Modscan
Originally posted by WB isme on 25 March, 2013 - 2:34 am
Problem with energy meter using modscan
New Replies:
1) Have you tried looking at more than one data format? 2) Have you tried reading from another...
Topic: Communications systems and equipment.
from the modbus department...
Proview - modbus - plc
Originally posted by Joël van As on 19 March, 2013 - 10:21 am
Proview - modbus - plc
New Replies:
The link below is to a Chipkin's "Modbus for Field Technicians" document that covers...
Topic: Sensor technologies.
from the Instrumentation department...
Flange type DP Transmitter zero error
Originally posted by Ravindra on 17 March, 2013 - 1:10 am
Flange type DP Transmitter zero error
New Replies:
What is the "top side" connection"? dry leg? wet leg? capillary with a diaphragm...
Topic: Continuous process industries, DCS questions.
from the instrumentation department...
Instrumentation Books
Originally posted by allenbradley06 on 16 March, 2013 - 4:22 pm
Can you recommend a book about instrumentation and process control in a petrochemical plant and oil and gas
New Replies:
A frequent control.com contributor, Walt Boyes, is author of an excellent instrumentation book,...
Topic: Information resources, documentation.
from the Instrumentation department...
generating Hook-Up drawings for field instruments
Originally posted by Adeyinka Adekanmi on 7 March, 2013 - 3:02 pm
Material For preparing Hook up drawings
New Replies:
You can read Liptak's comment on loop diagrams for smart instruments here: ...
Key term: Instrument Loop Diagram ...
Topic: Sensor technologies.
from the Forum department...
Bearing Temperatures
Originally posted by Owais on 5 March, 2013 - 2:21 am
Bearing Temperatures hunting
New Replies:
Installing Instrumentation on Insulated Bearings ...
Topic: Communications systems and equipment.
from the Instrumentation Engineering department...
Is there any difference in signal transmitted in HART and Fieldbus or not?
Originally posted by Mirza Vaseem Raza on 6 March, 2013 - 4:49 am
Is there any difference in signal transmitted in HART and Fieldbus or not?
New Replies:
http://iamechatronics.com/notes/general-engineering/294-h1-foundation- fieldbus-physical-layer...
Topic: Sensor technologies.
from the Forum department...
T/C extension wires
Originally posted by d- on 3 March, 2013 - 1:14 pm
use of neutral extension wires in industrial temperature measurement
New Replies:
Curt, Those L&N's you remember are probably not that much different from the one on display...
Neutral extension leads (as described in "Temperature Measurement", 1999, CRC Press)...
I hope not many, but I have seen it. If by "neutral extension wires" you mean that...
Topic: PLCs and related questions.
from the Modbus links department...
modbus reading not actual
Originally posted by Ahmed El-dosoky on 4 March, 2013 - 12:17 am
Not getting real values and rapid changing Modbus reading from Allen Bradly PLC
New Replies:
The data in the slave/server (presumably data in the PLC?) is in a format that has to be...
For example, what reading do you expect? As examples, what readings are you getting that do appear...
Topic: PLCs and related questions.
from the Siemens PLC department...
Adding Pyrometers to an assembly line
Originally posted by Halo on 3 March, 2013 - 3:01 pm
Incorporating Pyrometers into an assembly line
New Replies:
I guess it depends on the complexity of the pyrometer and what the intention is. Is the...
Topic: Sensor technologies.
from the I & C department...
Rosemount Level transmitter Trouble
Originally posted by Benjamin on 2 March, 2013 - 6:19 am
Why are my Rosemount 3100 Level transmitter readings seem wrong (Lower than expected) even when my tank level is high?
New Replies:
If the readings are always low, then the reference level point and the bottom level points are...
Originally posted by remith on 15 February, 2013 - 1:27 am
will the reading of a differential pressure transmitter change if we use a capillary tube?
New Replies:
It depends on whether you have one remote seal on an open tank or two remote seals on a closed tank....
If you have two remote seals, one at the bottom with another one at the top, then you can move the...
Theoretically, the fluid in the capillary should transmit the pressure the same as tubing. But...
Topic: Engineering and workplace issues.
from the Forum department...
Minimum voltage for Hart communication
Originally posted by Marcos Escobar on 15 February, 2013 - 9:39 am
Need you opinion on this topic: Minimum voltage for Hart communication
New Replies:
It's Ohms Law. To drive the same current through greater resistance requires a higher voltage: ...
The vendor assertions about minimum voltage are indeed correct. What you've missed is the minimum...
Topic: PLCs and related questions.
from the Obsolete Meters department...
Digital Panel Meters
Originally posted by RK Sastry on 16 February, 2013 - 12:02 am
Suggestions for Obsolete panel meter replacement
New Replies:
In the US, those are known as 1/8 DIN panel meters which designed to fit in the same panel cutout...
Topic: PLCs and related questions.
from the Automation List department...
Flow totalizing from analog input
Originally posted by rta53 on 26 February, 2003 - 11:48 am
On a system consisting of a SLC 5/04 and a Panel View 1000, we want to display a running total from Signet Flow transmitters...
New Replies:
Just because the previous posts are a decade old, does not invalidate them. Same situation today...
Originally posted by RV on 9 February, 2013 - 11:44 am
I could not communicate with my PC when i connected the MM LDM 7835 to my PC
New Replies:
Assuming your software actually talks through a serial port, you need to check - Windows'...
Topic: Continuous process industries, DCS questions.
from the Instrumentation department...
Motorized control valves
Originally posted by Govind on 24 January, 2013 - 5:13 pm
How does a motorised control valve works?
New Replies:
It's not a problem if one is clairvoyant, but I'm not. Some MOV's use 4-20mA input. Some...
A major American manufacturer or two cannot provide wiring diagrams without the device's serial...
Topic: Sensor technologies.
from the Forum department...
compensation cable in tc
Originally posted by Charles on 6 February, 2013 - 9:54 am
about compensation cable info reqirements
New Replies:
Thermocouple extension cable is required because it completes the measurement, which is the EMF...
Topic: PLCs and related questions.
from the Automation List department...
Honeywell S9000 serial communication
Originally posted by Deepak C Mohan on 6 February, 2013 - 3:29 am
Pin Configuration for 25 pin RS232/RS 485 pin
New Replies:
If the information is available anywhere, it's probably in the S9000 Communications reference...
Select Page: 1 2 3 4 5 6 Next
 
 

Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2013 Nerds in Control, LLC. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.


Fortune
If someone had told me I would be Pope one day, I would have studied
harder.
-- Pope John Paul I
Advertise here
Advertisement
our advertisers
Help keep our servers running...
Patronize our advertisers!
Visit our Post Archive