Member Information and Posts by Mpac
Topic: Human-Machine Interface and SCADA.
from the Mark V department...
Mark V HMI PC failure
Originally posted by ananymous on 26 August, 2012 - 9:22 pm
Mark V HMI PC failure
New Replies:
CSA, I believe the dongle is for TCI as only the Servers have dongles, Viewers do not. But I'm...
Actually, if you read the posters original message, the hard drives are plugged into port 0 and 2,...
It sounds like we have a similar setup, and we have restored our HMI's using the software. The...
Topic: Continuous process industries, DCS questions.
from the Instrumentation department...
Control valve not working with high pressure
Originally posted by Arnel Chumacera on 2 March, 2012 - 1:05 am
Control valve not working properly in service with high pressure on the line
New Replies:
I have seen this before when the valve was installed backwards. The upstream pressure should help...
Topic: Power generation equipment control.
from the I&E department...
CTG Exhaust Pressure Trip
Originally posted by MPAC on 27 December, 2011 - 1:39 pm
Cause of Exhaust Pressure spikes on 7FA
New Replies:
We did find our problem. We were told to try heat tracing the tubing and I found it hard to...
> you confirm the transmitter? or remove to lab check the current of transmitter. Transmitter...
Topic: Sensor technologies.
from the Private department...
Selection Of Gas Flow meter
Originally posted by Mark on 13 January, 2012 - 1:20 am
Selection of gas flow meter?
New Replies:
I believe a very accurate meter would be a coriolis meter. I would look at Micromotion coriolis...
Topic: Power generation equipment control.
from the Mark VIe department...
Hart Tri-Loop not working with GE Mark VIe
Originally posted by John Gardner on 27 June, 2011 - 3:00 pm
Tri-Loop not working: Burst Mode Message Timeout error
New Replies:
From my experience with our 3095MV transmitters you cannot configure the parameters with a 375...
Topic: Power generation equipment control.
from the Instrumentaiton department...
LVDT in GT
Originally posted by AK on 4 June, 2011 - 1:22 pm
GCV/SRV, LFBV and IGV
New Replies:
CSA; Yes I would agree that the purpose of Calibrating LVDT feedback is to ensure the LVDT...
CSA; Sorry, I guess I misread what you had said in the paragraph below. When I check...
CSA; I have been thinking about your post about the LVDT %100 calibration position. As you...
Topic: Power generation equipment control.
from the Instrumentation department...
View 2 tool
Originally posted by G.Rajesh on 4 April, 2010 - 5:36 am
What is the use of view2 tool? will it collect the past data to future data?
New Replies:
View2 is used to collect a group of data after you type in the command and press the enter button,...
Topic: PLCs and related questions.
from the I&E department...
Failed Siemens S7-200 replacement
Posted by MPAC on 3 April, 2010 - 2:51 pm
Programming a new Siemens S7-200
Topic: Power generation equipment control.
from the mk5 department...
Diagnostic alarm in MarkV
Originally posted by mksod on 24 March, 2010 - 9:55 am
In mk5 is there a list of all diagnostic alarms?
New Replies:
IN F: open ALARM.DAT Scroll down to QD alarms and find alarm #. eg. QD 1737 TCE1 Power...
Topic: Power generation equipment control.
from the Forum department...
GE OPFLEX Experience
Posted by MPAC on 24 November, 2009 - 6:01 pm
anyone have any experience with OPFLEX on a GE 7FA gas turbine
Topic: Power generation equipment control.
from the Forum department...
Mark V communications
Originally posted by mpac on 27 September, 2009 - 7:44 am
What would be required to connect to the Mark V network using the network switch provided for the Viewers and DCS.
New Replies:
Thank-you very much CSA. I was able to remote PC in to one of the servers. Also curious though...
Select Page: 1
 
 

Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2013 Nerds in Control, LLC. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.


Fortune
Those who make peaceful revolution impossible will make violent
revolution inevitable.
-- John F. Kennedy
Advertise here
Advertisement
our advertisers
Help keep our servers running...
Patronize our advertisers!
Visit our Post Archive