Member Information and Posts by apps_manI have a problem when I want to read the modbus of SHARK 100, because I can't read 32-bit IEEE floating point format in VIJEO DESIGNER 5.0.
New Replies:
There is an option for each device communications driver to change the double word order. If the FP...
Hi Every one I wanna knw hw to configure the W@de RTU W315 for GPRS modem.
New Replies:
I emailed you the latest manual. Hope that it helps....
need to download EARS LOADABLE
New Replies:
I have already sent you the documentation. Your email server blocks the zip file....
Read slave modbus from CPU Quantum.
New Replies:
I too was confused by the original question. The issue is not with Modbus function codes but with...
You are correct. Unfortunately, the company that originated Modbus protocol did not elect to...
Does anyone know of multiple vendors of USB modbus plus devices?
New Replies:
This module works fine. Only issue is to use the same USB port all the time. The driver only...
Need information on the Unity's connectivity
New Replies:
If you connected the NOE or the Processor Enet port to a switch (Yes you can program via the...
Communication
New Replies:
In the Vijeo Designer Software, configure the target communication parameter (e.g. PLC) for IEC...
Trouble establishing communications between a Quantuam 311 CPU programmed in Unity and Wonderware InTouch 9.5 and SA85 I/O Server ver 8.1
New Replies:
Set the serial port parameters for the M340 cpu by "double clicking" on the serial port....
1
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2009 Nerds in Control, LLC. All rights reserved.