Member Information and Posts by gillani
Topic: Power generation equipment control.
from the Engineering department...
3 Phase Alternator
Posted by Ali on 23 November, 2012 - 5:05 am
When we restart the Alternator and just after excitation REVERSE Power relay active, after 45 sec it was manually reset (with out main VCB closing)
Topic: Engineering and workplace issues.
from the Electrical department...
Gearing on 1500 KW Motor
Posted by Ali on 13 March, 2012 - 4:28 am
Controlling the high torquing and beneficiary on 1500 KW Motor
Topic: Power generation equipment control.
from the Power Generation department...
Steam Turbine Back Pressure
Posted by Ali on 19 February, 2012 - 12:10 am
Back pressure Steam Turbine at inlet steam Pressure
Topic: Motion control, servos, steppers, etc.
from the Control department...
ABB LV Drives
Posted by Ali on 10 November, 2011 - 1:30 pm
what is the difference between AGDR-62CS & AGDR-71CS of ABB IBBT Driver units
Topic: Engineering and workplace issues.
from the Electrical department...
ABB AC Drive ACS800-07 fault
Posted by Hussain on 5 November, 2011 - 3:58 am
Restarting ABB type ACS800-07 drives after 8 month shutdown, the drives installed in 2006 & 2008 go to fault INV SC.
Topic: Power generation equipment control.
from the Power department...
Steam Turbine
Posted by Gillani on 26 July, 2011 - 4:33 am
we need to operate turbine on 0.1 Bar back pressure, are this safe and what are the disadvantageous to reduced Exhaust pr.
Topic: Engineering and workplace issues.
from the electrical department...
insullation class for altornators
Posted by Hussain on 22 January, 2011 - 11:23 am
what is recommended limit of tripping for over temperature?
Topic: Engineering and workplace issues.
from the Electrical department...
Calculating NGR
Posted by Ali on 30 December, 2010 - 2:08 am
Calculate NGR for Alternators & Transformers
Topic: Engineering and workplace issues.
from the Electrical department...
power transformer
Originally posted by Ali on 19 December, 2010 - 3:49 am
Want run three transformers in parallel for export power to national Grid, what about neutral wire?
New Replies:
Dear, i have mail you single line, my question is what is the coordination of neutral earthing? ...
Topic: Engineering and workplace issues.
from the Electrical department...
Excitation for Alternator
Originally posted by Ali on 11 December, 2010 - 10:42 am
Alternator 15 MW, 5500 Volt, with field Excitation 12 Volt and 30 Amp. Can we change field winding for 70 Volt?
New Replies:
the specification as under, Stator data Volt 5500 +- 5% Current 2000 Amp speed ...
Yes I am Sure Field Voltage are 12 V and 30 Amp. and rotor Amp 900/1600 Amp...
Topic: Engineering and workplace issues.
from the Electrical department...
RMT for turbine speed control
Posted by Hussain on 8 December, 2010 - 7:25 am
when we close the VCB, we are unable to control speed for control load
Topic: Engineering and workplace issues.
from the Electrical department...
Checking Alternator Parameters
Posted by Hussain on 12 November, 2010 - 1:17 am
Parameters to check when running alternator after long shutdown
Topic: Engineering and workplace issues.
from the Electrical department...
Alternator questions
Posted by Hussain on 31 October, 2010 - 8:42 am
what happened with alternator if i put AVR output to fields of alternator exciter, on wrong polarity?
Topic: Continuous process industries, DCS questions.
from the Boiler department...
Steam property
Posted by Ali on 18 September, 2010 - 4:42 am
super-heated steam Boiler,37 Kg/Cm2 at 417deg C. after reducing pressure, the temperature decreased.
Topic: Engineering and workplace issues.
from the Electrical & Instrument department...
3 phase Alternator
Posted by Hussain on 31 July, 2010 - 3:31 am
Is it possible to run 3 phase alternator anti-clockwise instead of clockwise?
Topic: Engineering and workplace issues.
from the Electrical & Instrument department...
Transformer
Originally posted by Hussain on 29 May, 2010 - 5:09 am
If we use this transformer as step up, are the losses are same or will be increase?
New Replies:
are we calculate actual losses?...
Topic: Engineering and workplace issues.
from the Electrical department...
Alternator synchronizing
Posted by Hussain on 20 February, 2010 - 2:30 am
After alternator synchronized with national grid, increasing load the KW and Ampere meters shows hunting
Topic: Engineering and workplace issues.
from the Electrical department...
3 Phase transformer neutral
Originally posted by Hussain on 20 January, 2010 - 2:53 am
Can i connect Neutral to ground directly or use resistance in transformer
New Replies:
Dear Phil Corso, I have search on control.com but not find. my question is that, my transformer...
Topic: Engineering and workplace issues.
from the Electrical department...
Earthing and NGR Resistance
Posted by Hussain on 18 December, 2009 - 2:56 am
Connecting neutral of both transformer to earth and what is the NGR Resistance
Topic: Engineering and workplace issues.
from the Electrical department...
Seimens 6000 volt Alternator
Originally posted by Hussain on 27 July, 2009 - 4:31 am
Alternator stator design voltage are 6000 Volt, want to operate on 3300 Volt
New Replies:
our maximum power requirement is 8 MW from alternator due to prim mover capacity of 9 MW. please...
I want more clarification, my exciting Power house is at 3.3 KV Bus. now i want to avoid extra...
Topic: Engineering and workplace issues.
from the Electricl department...
Turbo Alternator
Posted by Hussain on 15 April, 2009 - 1:10 am
Turbo alternator insulation resistence
Topic: Engineering and workplace issues.
from the Electrical department...
Alternator
Posted by Hussain Ali on 29 October, 2008 - 7:25 am
Tests for 15000 KVA Alternator, Siemens make, 6 KV.
Select Page: 1
 
 

Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2013 Nerds in Control, LLC. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.


Fortune
Campus sidewalks never exist as the straightest line between two
points.
-- M. M. Johnston
Advertise here
Advertisement
our advertisers
Help keep our servers running...
Patronize our advertisers!
Visit our Post Archive