Select Page: 1
Control.com member...
Member Information and Posts by gisaac
Topic: Engineering and workplace issues.
from the Forum department...
Which DCS to select?
Originally posted by JuliusTheCeaser on 15 December, 2009 - 7:16 pm
Comparison among different makes of DCS used to control medium size of process
New Replies:
One of our power plants has been using a Yokogawa CS3000 for the past 8 years and have not had a...
Originally posted by Maint on 12 November, 2009 - 5:39 am
what is water injection system in gas turbine ?
New Replies:
Water injection is used to help control NOX emmissions. Water is mixed with the fuel as the fuel...
Topic: Engineering and workplace issues.
from the Forum department...
Mark V C core problems
Originally posted by gisaac on 2 September, 2009 - 11:58 am
C Core repeatedly fails. Causes I/O to freeze.
New Replies:
> What have you done to try to resolve the problem other than resolve a ground? < ...
The IO froze again this past Friday. This is the information I received from the technicians. ...
The I/O that is freezing is on the CTBA board. This unit is used to run a 7EA turbine/gen set,...
Topic: Human-Machine Interface and SCADA.
from the Forum department...
Mark V Logic
Originally posted by gisaac on 13 August, 2009 - 9:32 am
Where is the logic located on the HMI?
New Replies:
Thanks for the information. I will probably be going out to the site this week and download the...
Topic: Communications systems and equipment.
from the Forum department...
OPC Write
Posted by gisaac on 1 May, 2009 - 8:42 am
Is there a way to disable write capability on an OPC server?
Topic: Communications systems and equipment.
from the Mark VIe department...
Mark VIe protocols
Originally posted by gisaac on 15 January, 2009 - 12:39 pm
Does the new Mark VIe support DNP 3.0?
New Replies:
Don't we wish that they did!!!...
Topic: Human-Machine Interface and SCADA.
from the Forum department...
Cimplicity SQL Help
Posted by gisaac on 10 December, 2008 - 12:25 pm
Event Logger not working...
Topic: Software, including programming, OS issues, etc.
from the INSTRUMENT department...
CENTUM CS3000
Originally posted by saeed on 24 November, 2008 - 10:35 am
Writing and logic in CENTUM CS3000
New Replies:
They have training in Newnan, GA. It's a two week school. Covers everything from graphics building...
Originally posted by James on 2 October, 2008 - 1:03 am
Advantages of Mark VI and Mark V over Mark IV?
New Replies:
Our company has two Frame 5s that have the Woodward Micronet control system on them. I believe...
Topic: Engineering and workplace issues.
from the The Min-Max-What's The Impact department...
GE MARK IV/V/VI Interface Options
Originally posted by Michael Toecker on 24 September, 2008 - 2:11 pm
Calling for comments and/or observations regarding the different methods of interfacing a GE MARK IV/V/VI system to a DCS.
New Replies:
Mike, How many points are you needing from one system to the other? We run two Cimplicity...
Topic: Human-Machine Interface and SCADA.
from the Mark V department...
Mark V HMI Upgrade
Originally posted by dinster on 18 September, 2008 - 1:34 am
Mark V HMI upgrade possibility?
New Replies:
I have often wondered about what other people were doing when their HMIs or Arcnet cards die. We...
Select Page: 1
 
 

Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2013 Nerds in Control, LLC. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.


Fortune
Try to be the best of whatever you are, even if what you are is no
good.
Advertise here
Advertisement
our advertisers
Help keep our servers running...
Patronize our advertisers!
Visit our Post Archive