Member Information and Posts by mthines
User Picture
Topic: Power generation equipment control.
from the Forum department...
GE Frame 7EA Loss of Flame/TripOil
Originally posted by smd123 on 7 May, 2013 - 12:01 pm
GE Frame 7EA flameout/trip oil problem
New Replies:
Dear SMD, thanks for the update to your problem. Please keep up with the information, it is...
Stephen, I am still trying to get my head around your trip oil system, I wish I had a oil...
Topic: Power generation equipment control.
from the power generation department...
GTG starting clutches
Originally posted by Ayed on 23 April, 2013 - 5:53 am
We have in our gas turbine frame 7E a problem of failure to start due to starting clutch disengage.
New Replies:
I have assisted with installations of the SSS clutch on some older Frame 5 units replacing the...
Topic: Power generation equipment control.
from the Operation department...
IBH for DLN 1.0 Premix turndown
Originally posted by SB on 19 March, 2013 - 9:08 am
What are conditions for IBH Operation? What is impact of system frequency on its operation? did low frequency limit/restrict the IBH to remain close? and what is the impact of climate/atmospheric temperature with IBH.
New Replies:
Dear SB, typically the operation of IBH based on the position of the inlet guide vanes. This...
Topic: Power generation equipment control.
from the energy department...
fuel gas heating in 7fa
Originally posted by hulaimi on 22 March, 2013 - 9:34 pm
why we are heat gas in 7fa while not heat gas in 7EA machine?
New Replies:
Dear hulaimi, actually some 7EA machines do have heated fuel, but not as many as the 7FA machines. ...
Topic: Power generation equipment control.
from the Forum department...
Mark VI/Windows 7 Migration
Originally posted by GJRS on 7 June, 2012 - 10:11 am
Migrating from Mark VI running on XP to Mark VI on Windows 7.
New Replies:
Dear GJRS, I am running Toolbox and Cimplicity on a VM with no problems, basically created a VM...
Topic: Power generation equipment control.
from the Intermittent alarm department...
Mark VI alarm
Originally posted by madmax on 8 February, 2013 - 12:37 am
Having an intermittent alarm on HMI for GE Mark VI. It is as follows: "loss of DC power to DGP trip circuits"
New Replies:
Dear Max, thanks for the feedback. I will look forward to more information from you as you dig...
Dear Madmax, it would be most helpful, and allow us to help you best, if you can provide as much...
Topic: Power generation equipment control.
from the Control department...
Mark VI gas control fault
Originally posted by Wahidul Islam on 7 February, 2013 - 11:02 am
gas control fault shows in the alarm section of mark 4 gas turbine
New Replies:
Dear Wahidul, It is difficult to assist you since I cannot view the your logic exactly as it is...
Dear Wahidul, After reading CSA's post I reviewed my MKIV elementaries and I think the last...
Dear Wahidul, this is a very interesting problem you are encountering. I have reviewed some old...
Topic: Power generation equipment control.
from the control department...
Equivalent operating hours calculation
Originally posted by sandy on 5 February, 2013 - 4:34 pm
what determines eoh and eh counter reading?
New Replies:
Dear Sandy, Mohamad did a very nice job of presenting some factors for calculating equivalent...
Topic: Power generation equipment control.
from the Forum department...
9FA manhole to no.2 bearing
Originally posted by kamel on 30 January, 2013 - 9:58 am
9FA manhole to no.2 bearing
New Replies:
Dear Kamel, I agree it sounds very similar to a 7FA(I think the 9FA is a little bigger) as far...
Dear kamel, a picture would be worth a thousand words in this case. I am not familiar with...
Topic: Power generation equipment control.
from the Operations department...
7FA Gas Turbine Crank Cooling
Originally posted by Tom Murphy on 18 January, 2013 - 7:30 am
Is it recommended not to crank cool a 7 FA Gas Turbine too many times. We do a lot here for maintenance. Is there a limit?
New Replies:
Tom, I do not think there is a black and white answer to your question. This topic has been...
Topic: Power generation equipment control.
from the engineering department...
mark vi vcmi replacement
Originally posted by Lee YJ on 23 December, 2012 - 2:55 am
replacing vcmi without trip
New Replies:
Dear Lee YJ, first off it would be helpful if you provide more information as the the turbine or...
Originally posted by Lekie on 20 December, 2012 - 5:33 pm
TMR Mark VI does not reach its normal "Control" state
New Replies:
Dear Lekie, I would suggest using your toolbox software to look at diagnostics for "T"...
Topic: Power generation equipment control.
from the Forum department...
EX2000. 417 fault
Originally posted by Voyager2 on 8 December, 2012 - 12:47 pm
Ex2000. Fault 417 LARCTAFL
New Replies:
Dear Voyager2, sorry but I have been busy with other tasks. I am not sure which configuration...
Dear Voyager2, I do not know the EE's to check right off hand, I will do some looking at files...
Voyager2, yes I would say that it is possible that if you downloaded the file from another EX2K...
Dear Voyager, I am not really sure how this fault is related to your recent download, but...
Topic: Power generation equipment control.
from the Forum department...
modbus communication on MKVI HMI
Originally posted by attali abdelkrim on 13 December, 2012 - 2:06 pm
A strange behavior of modbus TCP/IP communication on MKVI HMI,
New Replies:
Dear attali abdelkrim, as CSA asked "When did this problem start?". You anwered after...
Topic: Power generation equipment control.
from the Maintenace department...
GTC starting system fails to accelerate
Originally posted by islaahi78 on 7 December, 2012 - 6:46 am
GTC starting system fail to continue during acceleration mode
New Replies:
Dear islaahi78, thank you for the feedback and I am glad that your issue has been resolved....
My only suggestion would be to check the adjustment of the proximity switch for the SSS clutch, if...
Topic: Power generation equipment control.
from the Freq Response department...
Preselect Load with Remote Control
Originally posted by Sean on 29 November, 2012 - 11:21 pm
Frequency Response with Remote Control (Mark V)
New Replies:
First of all to CSA, thank you for the MVP Kudos, I'll try not to let it go to my head. To Sean,...
Sean, I am going to chime in a bit, but most likely not answer all your questions, but at least...
Topic: Power generation equipment control.
from the Forum department...
Load Gear Oil Leakage GE 6B Gas Turbine
Originally posted by EserBp on 1 December, 2012 - 1:56 am
We had a Leak problem on Load Gear Reducer of Gas Turbine 6B GE supplied.
New Replies:
Dear EserBP, I am not very familiar with the 6B units but will offer these suggestions and...
Topic: Power generation equipment control.
from the Operation department...
Compressor Blow Off Valve
Originally posted by fai on 21 April, 2011 - 4:03 am
How to check compressor Blow Off Valve
New Replies:
Dear Paragkumar, I am not suggesting that it is a good idea to continue running with compressor...
Topic: Power generation equipment control.
from the Power department...
Differences between 7FA & 7FB
Originally posted by Ken on 25 November, 2012 - 5:18 pm
Differences between 7FA & 7FB
New Replies:
Ken the key difference is higher output obviously. This being achieved by a higher compressor...
Topic: Power generation equipment control.
from the MARK V department...
L63ET1H Switch trouble
Originally posted by Mark V on 25 November, 2012 - 6:10 am
L63ET1H alarm occurred on one of our GTs
New Replies:
Dear Mark V, that sounds like the most logical way to handle the situation, minimizing the risk,...
Dear Mark V, typically there are two exhaust pressure switches and possibly a transmitter to...
Topic: Engineering and workplace issues.
from the engineering department...
EX2K connection and questions
Originally posted by jose on 21 November, 2012 - 4:02 pm
need help on EX2K
New Replies:
Dear Jose, sorry but I cannot send the manuals by email. On the Controls Connect site I just...
Dear Jose, I would suggest you review the EX2K manuals GEH-6120 and GEH-6121. If you do not...
Topic: Power generation equipment control.
from the I & C department...
Explosion proof limit switches
Originally posted by sandy on 18 November, 2012 - 6:48 pm
bleed valve limit switches
New Replies:
Dear Sandy, I do not think you can assume that just because the compressor bleed valves are...
Topic: Power generation equipment control.
from the Forum department...
EX2000 lost communication with Mark VI
Originally posted by Ali_2013 on 11 November, 2012 - 4:03 pm
EX2000 lost communication with Mark VI
New Replies:
Dear Ali, I would be looking at the ACNA board and all the coaxial cables from the ACNA board to...
Topic: Power generation equipment control.
from the Forum department...
GE EX2000 Fault Codes
Originally posted by GEWannabe on 10 August, 2011 - 9:29 am
Does anyone have, or know where a list of all EX2000 Fault Codes can be found?
New Replies:
Dear GEWannabe, GEH-6121 is the Startup, Adjustment,and Troubleshooting guide for the EX2000 and...
Topic: Power generation equipment control.
from the MARK V department...
Fire protection L30CC alarm
Originally posted by Mark V on 19 November, 2012 - 11:38 am
L30CC alarm - Fire Protection system trouble
New Replies:
Dear MARK V, it would be very helpful to others trying to help you if you provide specific...
Topic: Power generation equipment control.
from the Controls department...
GAS LEAK TEST 9FA DLN 2.6+
Originally posted by JP on 28 October, 2012 - 2:56 pm
Questions about gas leak test for frame 9FA DLN 2.6+
New Replies:
Dear JP, I will be reviewing code I have for a newer 7FA. According to the code I have, I...
Dear JP, Not all controller code is the same so this may not be 100% applicable to your unit....
Originally posted by MashII on 8 October, 2012 - 10:31 am
Unit unable to maintain baseload control (droop) because of large grid swings (upto 51.8HZ on a nominal 50HZ grid system). Need a solution to keep unit stable when the grid frequency swings
New Replies:
Dear Mashll, I would suggest using the search feature of control.com to look for previous post...
Originally posted by Mohsin Raza on 8 October, 2012 - 3:07 am
GCV Reference Command and Feedback Difference
New Replies:
Dear Mohsin Raza, to add to MK6TA's comments. When a valve command vs actual position differs...
Originally posted by DNA on 29 September, 2012 - 8:11 am
Setpoint required for 26BA-1 on Frame V Turbine
New Replies:
Dear DNA, no worries, glad to be of help....
Dear DNA, I am not sure exactly which switch you are looking for a setting on. The title of your...
Topic: Power generation equipment control.
from the Forum department...
GE Proximetor vibration
Originally posted by Kamel on 26 September, 2012 - 6:16 pm
how to use the proximitor page in mark 6?
New Replies:
Dear Kamel, I have to agree with comments from CSA. The only information I might add is this. ...
Dear Kamel, My advice is to use the proximitor page of the HMI as just another "tool"...
Originally posted by Control on 31 August, 2012 - 11:12 am
I want to learn about L3CP contact. What is this contact? Thanks..
New Replies:
Dear Zihni. Signal L3CP. "L"=Logic not a hardware signal but logic. "3"...
Topic: Power generation equipment control.
from the ops department...
Runback on GE 7FA
Originally posted by Tom Murphy on 24 August, 2012 - 3:01 pm
Runback occurring on GE 7FA dual fuel turbine operating on liquid fuel
New Replies:
Dear CSA, I will not try to argue the operation of the droop logic with you, mainly because I...
Tom, glad to hear those two units are still running, and your still stuck there! As you well...
Topic: Power generation equipment control.
from the thermal generation department...
EX 2000
Originally posted by olympas olympio on 20 August, 2012 - 7:40 am
The alarm 379 ucp_ucc watchdog time outpops on the ex2000
New Replies:
Dear Olympas, this alarm does not have a very good description in the manuals. This alarm...
Topic: Power generation equipment control.
from the Operations department...
GT v ST loads
Originally posted by Andrew on 19 July, 2012 - 6:50 am
Rule of thumb
New Replies:
Andrew, thanks for the feedback!! ...
Select Page: 1 2 3 4 Next
 
 

Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2013 Nerds in Control, LLC. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.


Fortune
The church is near but the road is icy; the bar is far away but I will
walk carefully.
-- Russian Proverb
Advertise here
Advertisement
our advertisers
Help keep our servers running...
Patronize our advertisers!
Visit our Post Archive