Topic: Power generation equipment control.
from the Please Help department...
Generator Hydrogen Loss
Originally posted by Dfoster on 20 February, 2014 - 3:29 pm
Need help in determining cause of H2 Loss.
New Replies:
We have F7E GT. We had same problem with excessive H2 loss at one of the GT. We found out after...
Originally posted by Controman on 25 February, 2013 - 5:48 pm
What specificity does R controller have with the DC LED?
New Replies:
Excellent and very thorough description, thank you SIR...
Topic: Power generation equipment control.
from the Operations, VRA department...
IGV temperature control in combined cycle operation.
Originally posted by EDMUND ADU on 23 October, 2012 - 3:50 pm
What is the advantage enabling Inlet Guide Vane temperature control in combined cycle operation?
New Replies:
Well explain CSA, I am still confuse about the inverted slop of exhaust temp Vs CPD/FSR bias. Any...
Topic: Power generation equipment control.
from the master tech department...
Hydrogen seal oil
Posted by sardar9 on 1 September, 2011 - 4:33 am
H2 seal oil enlargement tank
Topic: Power generation equipment control.
from the ops department...
Mark VIe questions
Posted by sardar9 on 27 March, 2011 - 5:27 am
We have 4 GTG F-7E frame and all are upgraded from Mark IV to Mark VIe. I have a lot of questions about its topology. Here I am working as an operator but very curious about MarkVIe.
Topic: Power generation equipment control.
from the operation department...
compressor discarge pressure
Originally posted by charge Engineer on 24 December, 2010 - 2:01 am
the relation between CPD and some parameters
New Replies:
Reposting, I suspect first reply didn't go through. I think there is no relationship between CPD...
Topic: Power generation equipment control.
from the NJDEP Is Scary. Help! department...
Frame 7EA Post Outage Emissions Trouble
Originally posted by Justin on 9 December, 2010 - 4:18 pm
Frame 7EA post combustion section rebuild won't make NOX emissions and exhaust temp not controlling properly
New Replies:
For your Mark IV, I don't think that just by selecting peak temp (from 2020 to 2035 or 2055) will...
Topic: Power generation equipment control.
from the Sync Problems department...
GE MKV EX2000 Sync Issue
Originally posted by B. Grave on 19 December, 2010 - 7:03 pm
All status checks OK, no alarms, but 7EA mkv will not sync.
New Replies:
We have updated our Frame 7E speedtronic from M4 to M6e recently (first in US or we were testing...
Select Page: 1
 
 

Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2014 Nerds in Control, LLC. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.


Fortune
A diva who specializes in risqu'e arias is an off-coloratura soprano ...
Advertise here
Advertisement
our advertisers
Help keep our servers running...
Patronize our advertisers!
Visit our Post Archive