Generator Hydrogen Cooling System

G

Ghassan Sleiman

This is a great thread. Does anyone have any data on the effect of hydrogen purity of the Generator. What would be loss of efficiency of a Generator if the purity of H2 begins to decrease.

On another note. I have worked on many station in the middle east where they have on site Generation. What I found was that if you select the right Company, you can make your own hydrogen for years and years. But there are many more failed On-site Generation Companies. Make sure you select the right one. There are only 3 that come to mind.
 
> I have a PowerPoint presentation I can send you but I do not know how to add attachments to the site, Do you know? <

If you do not mind, then May I ask you to send me copy at cudc1 at yahoo dot com, please
 
>> I have a PowerPoint presentation I can send you but I do not know how to add attachments to the site, Do you know? <<

Could you perhaps forward that powerpoint presentation to me. My email is: heymie at mailbox dot co dot za

I am looking for more efficient ways to scavenge hydrogen from the generators. Which company can I speak to about good scavenging units?
 
there is always out gassing of any new oil in the system as it heats up, and visible when the pressure is reduced in the return vessel.

once the oil is out-gassed has any work been done with H2 padding of the oil reservoir?
 
Very interesting information. Any chance you know (or can point me in the right direction) to learn about how much power the whole cooling system draws? That is, how much recirculating power is there?

Thanks.

> The concepts of a hydrogen-cooled generator are very simple. As current
> flows in a conductor, heat is generated. A generator has a lot of conductors and a lot of current flowing through the
>conductors, generating a lot of heat.

---- snip ----
 
> I have a PowerPoint presentation I can send you but I do not know how to add
> attachments to the site, Do you know?

Hello!!

Can you send me this presentation please. My e mail address is
sim_4144[at]yahoo[dot]com

Thanks in advance
 
>> I have a PowerPoint presentation I
>can send you but I do not know how to
>add
>> attachments to the site, Do you
>know?
>

I would be very appreciative of a copy of the presentation on hydrogen cooling. My e-mail is dave(dot)wolff(at)protonenergy.com
 
Why the amount of CO2 required for replacing air & hydrogen is different. I read somewhere that less amount is required to purge air from generator casing. Can anybody help me?
 
> I have a PowerPoint presentation I can send you but I do not know how to add
> attachments to the site, Do you know?

Hello !!! May I request your power point presentation. My e mail
sim_4144[at]yahoo[dot]com

Thank for your time
 
> I have a PowerPoint presentation I can send you but I do not know how to add attachments to the site, Do you know?

Hi Mr retired,

please send me power point attachment for H2 cooling, I really appreciate that. My e mail is sim_4144[at]yahoo[dot]com
 
> I have a PowerPoint presentation I can
> send you but I do not know how to add
> attachments to the site, Do you know?

I really appreciate if you can e mail me power point presentation of H2 cooler system.

Thanks. My e mail:
[email protected]
 
> I have a PowerPoint presentation I can
> send you but I do not know how to add
> attachments to the site, Do you know?

I really appreciate if you can e mail me power point presentation of H2 cooler system.

Thanks. My e mail:
[email protected]
 
M

Maroun Slaiby

Hello my Name Is Maroun and i am planning to an invention of Hydrogeen cooling system for House kitchens, any tips on that? I am not that experienced in that Field but just have the Idea to develop. Thank you
 
> I have a PowerPoint presentation I can
> send you but I do not know how to add
> attachments to the site, Do you know?

Is it possible to get a copy of your presentation that you so graciously offered. Either a native format or pdf will be greatly appreciated and can be sent to mr2jzherring at aim dot com (I don't know if real emails get through). And thank you in advance.
 
Of late we have facing a problem of low Dissolved Oxygen (1.1 ppm) in Stator water system. Hydrogen consumption has increased as compared to other running units. I would like to know how to collect sample from Gas trap and what analysis to be carried out to confirm the hydrogen leakage?

Thanks,
Devendra Pandey
 
Dear Sir,

Can Nitrogen be used as change-over gas for Hydrogen instead of CO2, if yes/no, why?

-Krishna
 
Top