Reversing an Allen Bradley Servo

Should be a pretty simple question, y'all. I've just never done this.

An A-B 2094-AM02 module driving an exit conveyor in a vacuum sealing machine. The short belt is geared (MAG) to the upstream chains and receives two rows of product. a MAM then moves the rows to the end of the belt, and then a pair of MAMs drops one and then the other row onto a take-away belt.

We have to move the motor from the right to the left side, and so we have to reverse direction.

Can I just change polarity on the property panel hookup tab, or should I (or must I) execute one of the tests? Feedback or Command and feedback. If so, which?

Thanks in advance.
 
J

James Ingraham

You can just change the motion polarity in the property panel. No need to do a test, since you know it's going to invert.

-James Ingraham
Sage Automation, Inc.
 
Top